Archive for October 17th, 2023
Specification Model: LC-V550 Material: Aluminum, Copper, Stainless Steel Color: Silver Power: 550W Voltage: 220V/50Hz Rated Speed: 1440 rpm Inlet Diameter: 1/4” Max Vacuum: -900mBar Noise:? 62dB(A) Operating Environment: -5? 45? / 23113? Exhaust Volume: 102L/min / 3.6cfm Number of Cylinders: 2 Number of Cooling Fans: 2 Temperature Rise:? 85K Gross Weight: 10kg/22.05lbs Net Weight: 9kg/19.84lbs Product Size: 281522cm/115.98.7in Package Size: 29.52516.5cm/11.619.846.5in. Industrial 2 Cylinders Vacuum Pump Air Conditioning Refrigeration 3.6CFM 550W. Vacuum pump with a high-quality copper motor that is more energy efficient and silent. The cast aluminum housing with excellent corrosion. Vacuum pump more durable, robust, and. Vacuum pump is suitable for a wide range of applications, such as medical compressors, air tools, textile machinery, sandblasting, painting, plastic machinery compressors, tire inflation. It is a wise choice for you. This machine adopts a cast aluminum shell, delicate aluminum conduit, copper wire motor, and stainless steel screws. It has enough mechanical strength, strong oxidation. What’s more, it adopts high precision and hardness silent bearing, and the bearing is high-temperature. And long service life. This machine has two cooling fans, one on each side of the left and right. The temperature rise is less than 85K, so you do not have to worry about the safety problems caused by the high temperature of the machine during use. This machine uses a copper wire motor, which is more energy efficient and silent. An aluminum wire, the heat generation is low and the current is smooth. So the heat will not be wasted, and it has advantages in energy consumption, low carbon, and. The rated speed of the product reaches 1440rpm, and the high quality bearings greatly help you to improve the efficiency and reduce the working time. The way of lubrication of this machine is. Air compression, so it is safer to use and you don’t need to worry about the maintenance of the vacuum pump. It saves a lot of energy and time for you. The two cylinders of this machine are hardened inside, so they are more. To friction and high temperature. Because of this, the service life of the machine will be longer. The machine is equipped with shock absorbing pads, which can effectively prevent the machine amplitude from being too large to hit with other objects. It can protect the machine well and effectively extend the service life of the machine. The machine is equipped with a silencer outside, and the noise is less than or equal to 62dB(A). The use of this machine can provide you with a quieter working environment, and you no longer have to be annoyed by the loud environmental noise. Suction Cup Foot Pads. The enlarged round suction cup foot pads can effectively increase the contact area between the machine and the desktop, thus making the machine more stable. And it can further reduce the amplitude of the machine, thus preventing the machine from damage caused by collision. The steel valve piece used in this machine is strong in toughness and good in stopping air, which can not be deformed under the long time operation of the machine and effectively increase the service life of the machine. This air compressor head can be used for spray gun painting, air guns, nail gun nailing, auto repair, etc. Vacuum pump is powerful and suitable for medical compressors, air tools, textile machinery, sandblasting, painting, plastic machinery, compressors, tire inflation, etc. Rated Speed: 1440 rpm. Operating Environment: -5? 45? / 23113? Exhaust Volume: 102L/min / 3.6cfm. Number of Cylinders: 2. Number of Cooling Fans: 2. Gross Weight: 10kg/22.05lbs. Net Weight: 9kg/19.84lbs. Product Size: 281522cm/115.98.7in. Package Size: 29.52516.5cm/11.619.846.5in. All Accessories Needed for Installation. Please allow the slight color difference caused by the shooting light and 1-3cm error due to manual measurement. Please make sure you do not mind before you order. France, Germany, spain, Italy. Feedback is very important to us. It is impossible to address issues if we do not know about them! Please keep the original box or packaging within 15days since item received. Your satisfaction is our ultimate goal. We work hard to earn your trust and future business. A If you receive a defective item, you may return it or ask for a discount. Due to time zones, our reply to your questions may not be immediately. If it’s non-workdays, please kindly be patient and wait till Monday.
ANCEL AC3000 digital manifold is a professisional instrument for installation, testing and maintenance of refrigeration equipment suchas air conditioners and cold stores. It combines 2-way pressure test, dual temperature measurements (with optionaldual temperature probes), a 32-bit digitalprocessor and a large LCD in one easy-to-useinstrument with the following main functions. Pressure and Saturation Temperature. Pressure Leak Test with recording. Direct T1 T2 Temperature, Real-timeSuperheat and Subcooling Simultaneously Display with Optional Two Clamp-onTemperature Probes. 5.89 Refrigerant Profiles Stored in The Instrument. Automatic Multi-unit Pressure Conversion. Automatic Temperature? /? Conversion. It is the right one you have to do the job right. Turn off the blue valve and red valve. Turn on the instrument. Then verify that LCD displays the status of the pressure test. If not, press the function button to switch it. When the instrument is turned on, theremay be 10 digits in the high and low pressure display area. Press R+/ R- buttons, Unit button and? /? Button to select tested refrigerant and reading display respectively. If the clamp-on temperature probes havebeen connected to the instrument, the real-time temperature will be displayed. If not, no display of it. Connect the instrument to the refrigeration system according to thechart below. Turn on the refrigerant valve and gently press the pressure release valve to vent the air in the connecting hose. When the refrigeration system stops, turnon the high pressure valve (red valve) and fill with a certain amount of refrigerant and then shut the valve quickly. Run the refrigeration system, turn on the low pressure valve (blue valve), and fill with the refrigerant into the refrigeration system. After the filling is completed, shut the low pressure valve (blue valve) and refrigerant valve. Let the refrigeration system running. Shut down the refrigeration system, make sure all valves are turned off, then disconnect the instrument between refrigeration system and source. Do not remove the high pressure valve connection until the pressure drops to the safe point. Then turn off the instrument. The filling operation of different equipment or refrigerants may vary. Please read carefully the relevant specific operation requirements for filling operation, so as to avoid damage to user or equipment caused by improper operation! The instrument can display the corresponding Evaporation Temperature(EV) and Condensation Temperature (CO) during the refrigerant pressure test. If the clamp-on temperature probes are connected to the instrument, LCD will display the real-time temperature in the spot T1 Sensor and T2 Sensor. Please make sure clamp-on temperature probes are connected as step 6 and contacted fully to the refrigeration pipes. The instrument can calculate the SH-Superheat and SC – Subcooling as long as the tested refrigerant ispreset and clamp-on temperature probes are connected well. Power on the instrument. Then make surethe LCD displays vacuum test status. If not, press the Function button to switch it. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. Press the unit button to adjust the reading unit. Connect the instrument to the refrigeration system. Connected clamp-on temperature probes will not affect the operation. Turn on the blue valve and red valve, andstart the vacuum pump. After the vacuum operation is completed, turn off the blue valve and red valve, then shut the vacuum pump. At this time, pressure leak test mode can be used to check leakage in the system (Please refer to Pressure Leak Test). The instrument is powered on with the blue and red valves turned off. Press the Function button to pressure leak test mode. The current pressure value is displayed at lower rightcorner of LCD. Press the Run/Stop button to start the leak test. At this time, the lower left corner records the initial pressure value; the lower right corner displays the instantaneous pressure value; the “P” display area shows the difference between the initial pressure value and the instantaneous pressure value. The time display shows how long the leak test will take, in hour : minute (HH:MM)format. All pressure units on the screen are the same. You can switch between the different pressure units by pressing the Unit button. 89 Kids of Refrigeant Database. Built-in 89 kinds of refrigerant NIST: According to AmericanNIST standard. R11 R113 R114 R115 R116 R12 R123 R124 R125 R1270. R13 R134A R14 R141B R142B R143A R152A R170 R21 R218. R22 R227EA R23 R236EA R245CA R245FA R290 R32 R401A R401B. R401C R402A R402B R403A R403B R404A R405A R406A R407A R407B. R407C R407D R407E R408A R409A R409B R41 R410A R410B R411A. R411B R412A R413A R414A R414B R415A R415B R416A R417A R418A. R419A R420A R421A R421B R422A R422B R422C R422D R423A R424A. R425A R426A R427A R428A R50 R500 R501 R502 R503 R504. R507A R508A R507B R509A R600 R600A R707 R7441C02 R1234. Wide Range of applications. Pressure test: gauge pressure. Pressure test unit: Kpa; Mpa; bar; inHg; PSI. Pressure test range: 0 Kpa – 6000 Kpa. Pressure test resolution: 1 Kpa. Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt. Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;). Vacuum test: relative vacuum. Vacuum test unit: Kpa; Mpa; bar; inHg; PSI. Vacuum test range: -101 Kpa – 0 Kpa. Vacuum test resolution: 1 Kpa. Temperature test unit: °C (Celsius), °F (Fahrenheit). Temperature test range: -40°C-150°C (-40°F-302°F). 0.1°C (-40°C-99.9°C), 1°C (100°C-150°C). 0.1°F (-40°F-99.9°F), 1°F (100°F-302°F). Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt. Power Supplies: 4 X 1.5V SIZE. AA / LR6 Battery not include. Ancel AC3000 refrgerantion Digital Manifold Gauge. Clamp on temperature probe socket. 5, R+/R-Refrigerant Type Selection Buttons. 10, High Pressure Button. 11, Refrigerant Obezervation Window. 12, Pressure release valve. 13, Refrigerant inlet/vacuum Pump inlet. 14, Low Pressure Valve. 15,1/4 inch high pressure inlet. 1 x AC3000 Manifold Digital Meter. 1 x Paper Box. 1 x User Manual. Clean the exterior with a damp cloth. Do not use harsh solvents. Keep screw connections clean and free of grease, clean with a moist cloth as required. Carefully blow out oil residues in valve block using compressed air. Replace the batteries when low battery power indication lights on in LCD. Low battery power supply. The instruments has low power sign. When it is displayed, it means the battery power is insufficient. At this time, the battery should be replaced as required in order to avoid affecting normal use. Damaged refrigerant hose orvalve stem. Please check the pipe connections and hoses before testing. If you find any damage, please replace them immediately to avoid improper use or accident. Failure of refrigerant filling. There is a valve core in the refrigerant inlet of the refrigeration system. When connecting the instrument, pay attention the two terminals of the hoses. Connect one terminal with a core to the refrigeration system, while another terminal without acore to the instrument. Every hose terminal comes with a nylonpad that is limited a certain life of using. Over use or other situation will make itdefective, which result in leakage. The instrument refrigerant inlet (the middle port of the instrument) has a port with valve core, which is used to vent the air in the hoes after connecting the refrigerant to the instrument. The port is equipped with a copper plug screw. It is required to tighten it every time before or after operation. Check the refrigeration system’s pipes and connectors. About Invoices: If an. Much appreciated to leave us your. ANCEL specializes in automotive intelligent diagnostics, detection and analysis systems, and automotive-related products for mechanics, repair shops, and DIYers. Our independent brand is. FOXWELL, LAUNCH, AUTOPHIX, OBDPROG ect. If there are any after-sales or pre-sales messages that can be sent to us, we will promptly handle them and provide satisfactory solutions. Model, make year, VIN. And tell me the main problem of your car, we will check and recommend a suitable product for you. Any questions, Please feel free to.