Archive for the ‘manifold’ Category

Posted by admin at July 6, 2024

Category: manifold

Tags: , , , , , , , , ,

Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test

Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
ANCEL AC3000 digital manifold is a professisional instrument for installation, testing and maintenance of refrigeration equipment suchas air conditioners and cold stores. It combines 2-way pressure test, dual temperature measurements (with optionaldual temperature probes), a 32-bit digitalprocessor and a large LCD in one easy-to-useinstrument with the following main functions. Pressure and Saturation Temperature. Pressure Leak Test with recording. Direct T1 T2 Temperature, Real-timeSuperheat and Subcooling Simultaneously Display with Optional Two Clamp-onTemperature Probes. 5.89 Refrigerant Profiles Stored in The Instrument. Automatic Multi-unit Pressure Conversion. Automatic Temperature? /? Conversion. It is the right one you have to do the job right. Turn off the blue valve and red valve. Turn on the instrument. Then verify that LCD displays the status of the pressure test. If not, press the function button to switch it. When the instrument is turned on, theremay be 10 digits in the high and low pressure display area. Press R+/ R- buttons, Unit button and? /? Button to select tested refrigerant and reading display respectively. If the clamp-on temperature probes havebeen connected to the instrument, the real-time temperature will be displayed. If not, no display of it. Connect the instrument to the refrigeration system according to thechart below. Turn on the refrigerant valve and gently press the pressure release valve to vent the air in the connecting hose. When the refrigeration system stops, turnon the high pressure valve (red valve) and fill with a certain amount of refrigerant and then shut the valve quickly. Run the refrigeration system, turn on the low pressure valve (blue valve), and fill with the refrigerant into the refrigeration system. After the filling is completed, shut the low pressure valve (blue valve) and refrigerant valve. Let the refrigeration system running. Shut down the refrigeration system, make sure all valves are turned off, then disconnect the instrument between refrigeration system and source. Do not remove the high pressure valve connection until the pressure drops to the safe point. Then turn off the instrument. The filling operation of different equipment or refrigerants may vary. Please read carefully the relevant specific operation requirements for filling operation, so as to avoid damage to user or equipment caused by improper operation! The instrument can display the corresponding Evaporation Temperature(EV) and Condensation Temperature (CO) during the refrigerant pressure test. If the clamp-on temperature probes are connected to the instrument, LCD will display the real-time temperature in the spot T1 Sensor and T2 Sensor. Please make sure clamp-on temperature probes are connected as step 6 and contacted fully to the refrigeration pipes. The instrument can calculate the SH-Superheat and SC – Subcooling as long as the tested refrigerant ispreset and clamp-on temperature probes are connected well. Power on the instrument. Then make surethe LCD displays vacuum test status. If not, press the Function button to switch it. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. Press the unit button to adjust the reading unit. Connect the instrument to the refrigeration system. Connected clamp-on temperature probes will not affect the operation. Turn on the blue valve and red valve, andstart the vacuum pump. After the vacuum operation is completed, turn off the blue valve and red valve, then shut the vacuum pump. At this time, pressure leak test mode can be used to check leakage in the system (Please refer to Pressure Leak Test). The instrument is powered on with the blue and red valves turned off. Press the Function button to pressure leak test mode. The current pressure value is displayed at lower rightcorner of LCD. Press the Run/Stop button to start the leak test. At this time, the lower left corner records the initial pressure value; the lower right corner displays the instantaneous pressure value; the “P” display area shows the difference between the initial pressure value and the instantaneous pressure value. The time display shows how long the leak test will take, in hour : minute (HH:MM)format. All pressure units on the screen are the same. You can switch between the different pressure units by pressing the Unit button. 89 Kids of Refrigeant Database. Built-in 89 kinds of refrigerant NIST: According to AmericanNIST standard. R11 R113 R114 R115 R116 R12 R123 R124 R125 R1270. R13 R134A R14 R141B R142B R143A R152A R170 R21 R218. R22 R227EA R23 R236EA R245CA R245FA R290 R32 R401A R401B. R401C R402A R402B R403A R403B R404A R405A R406A R407A R407B. R407C R407D R407E R408A R409A R409B R41 R410A R410B R411A. R411B R412A R413A R414A R414B R415A R415B R416A R417A R418A. R419A R420A R421A R421B R422A R422B R422C R422D R423A R424A. R425A R426A R427A R428A R50 R500 R501 R502 R503 R504. R507A R508A R507B R509A R600 R600A R707 R7441C02 R1234. Wide Range of applications. Pressure test: gauge pressure. Pressure test unit: Kpa; Mpa; bar; inHg; PSI. Pressure test range: 0 Kpa – 6000 Kpa. Pressure test resolution: 1 Kpa. Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt. Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;). Vacuum test: relative vacuum. Vacuum test unit: Kpa; Mpa; bar; inHg; PSI. Vacuum test range: -101 Kpa – 0 Kpa. Vacuum test resolution: 1 Kpa. Temperature test unit: °C (Celsius), °F (Fahrenheit). Temperature test range: -40°C-150°C (-40°F-302°F). 0.1°C (-40°C-99.9°C), 1°C (100°C-150°C). 0.1°F (-40°F-99.9°F), 1°F (100°F-302°F). Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt. Power Supplies: 4 X 1.5V SIZE. AA / LR6 Battery not include. Ancel AC3000 refrgerantion Digital Manifold Gauge. Clamp on temperature probe socket. 5, R+/R-Refrigerant Type Selection Buttons. 10, High Pressure Button. 11, Refrigerant Obezervation Window. 12, Pressure release valve. 13, Refrigerant inlet/vacuum Pump inlet. 14, Low Pressure Valve. 15,1/4 inch high pressure inlet. 1 x AC3000 Manifold Digital Meter. 1 x Paper Box. 1 x User Manual. Clean the exterior with a damp cloth. Do not use harsh solvents. Keep screw connections clean and free of grease, clean with a moist cloth as required. Carefully blow out oil residues in valve block using compressed air. Replace the batteries when low battery power indication lights on in LCD. Low battery power supply. The instruments has low power sign. When it is displayed, it means the battery power is insufficient. At this time, the battery should be replaced as required in order to avoid affecting normal use. Damaged refrigerant hose orvalve stem. Please check the pipe connections and hoses before testing. If you find any damage, please replace them immediately to avoid improper use or accident. Failure of refrigerant filling. There is a valve core in the refrigerant inlet of the refrigeration system. When connecting the instrument, pay attention the two terminals of the hoses. Connect one terminal with a core to the refrigeration system, while another terminal without acore to the instrument. Every hose terminal comes with a nylonpad that is limited a certain life of using. Over use or other situation will make itdefective, which result in leakage. The instrument refrigerant inlet (the middle port of the instrument) has a port with valve core, which is used to vent the air in the hoes after connecting the refrigerant to the instrument. The port is equipped with a copper plug screw. It is required to tighten it every time before or after operation. Check the refrigeration system’s pipes and connectors. Credit cards? Debit card? Apple Pay? Google Pay ect. Carrier and Logistics: All Orders are. Free repair for the devices. OBDII Code Reader, Car Diagnostic Tool, Truck Diagnostic Tool, EVAP Smoke Machine, Car Power Probe, Battery Tester. The price is reasonable and we have top rated after-sales service. Our main brand is. And we also sell other brands product, such as. FOXWELL, LAUNCH, THINKCAR, AUTOPHIX. GMT8 (9:00-18:00). From Monday to Friday.
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test

Posted by admin at March 23, 2024

Category: manifold

Tags: , , , , , , , , ,

Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test

Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
ANCEL AC3000 digital manifold is a professisional instrument for installation, testing and maintenance of refrigeration equipment suchas air conditioners and cold stores. It combines 2-way pressure test, dual temperature measurements (with optionaldual temperature probes), a 32-bit digitalprocessor and a large LCD in one easy-to-useinstrument with the following main functions. Pressure and Saturation Temperature. Pressure Leak Test with recording. Direct T1 T2 Temperature, Real-timeSuperheat and Subcooling Simultaneously Display with Optional Two Clamp-onTemperature Probes. 5.89 Refrigerant Profiles Stored in The Instrument. Automatic Multi-unit Pressure Conversion. Automatic Temperature? /? Conversion. It is the right one you have to do the job right. Turn off the blue valve and red valve. Turn on the instrument. Then verify that LCD displays the status of the pressure test. If not, press the function button to switch it. When the instrument is turned on, theremay be 10 digits in the high and low pressure display area. Press R+/ R- buttons, Unit button and? /? Button to select tested refrigerant and reading display respectively. If the clamp-on temperature probes havebeen connected to the instrument, the real-time temperature will be displayed. If not, no display of it. Connect the instrument to the refrigeration system according to thechart below. Turn on the refrigerant valve and gently press the pressure release valve to vent the air in the connecting hose. When the refrigeration system stops, turnon the high pressure valve (red valve) and fill with a certain amount of refrigerant and then shut the valve quickly. Run the refrigeration system, turn on the low pressure valve (blue valve), and fill with the refrigerant into the refrigeration system. After the filling is completed, shut the low pressure valve (blue valve) and refrigerant valve. Let the refrigeration system running. Shut down the refrigeration system, make sure all valves are turned off, then disconnect the instrument between refrigeration system and source. Do not remove the high pressure valve connection until the pressure drops to the safe point. Then turn off the instrument. The filling operation of different equipment or refrigerants may vary. Please read carefully the relevant specific operation requirements for filling operation, so as to avoid damage to user or equipment caused by improper operation! The instrument can display the corresponding Evaporation Temperature(EV) and Condensation Temperature (CO) during the refrigerant pressure test. If the clamp-on temperature probes are connected to the instrument, LCD will display the real-time temperature in the spot T1 Sensor and T2 Sensor. Please make sure clamp-on temperature probes are connected as step 6 and contacted fully to the refrigeration pipes. The instrument can calculate the SH-Superheat and SC – Subcooling as long as the tested refrigerant ispreset and clamp-on temperature probes are connected well. Power on the instrument. Then make surethe LCD displays vacuum test status. If not, press the Function button to switch it. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. Press the unit button to adjust the reading unit. Connect the instrument to the refrigeration system. Connected clamp-on temperature probes will not affect the operation. Turn on the blue valve and red valve, andstart the vacuum pump. After the vacuum operation is completed, turn off the blue valve and red valve, then shut the vacuum pump. At this time, pressure leak test mode can be used to check leakage in the system (Please refer to Pressure Leak Test). The instrument is powered on with the blue and red valves turned off. Press the Function button to pressure leak test mode. The current pressure value is displayed at lower rightcorner of LCD. Press the Run/Stop button to start the leak test. At this time, the lower left corner records the initial pressure value; the lower right corner displays the instantaneous pressure value; the “P” display area shows the difference between the initial pressure value and the instantaneous pressure value. The time display shows how long the leak test will take, in hour : minute (HH:MM)format. All pressure units on the screen are the same. You can switch between the different pressure units by pressing the Unit button. 89 Kids of Refrigeant Database. Built-in 89 kinds of refrigerant NIST: According to AmericanNIST standard. R11 R113 R114 R115 R116 R12 R123 R124 R125 R1270. R13 R134A R14 R141B R142B R143A R152A R170 R21 R218. R22 R227EA R23 R236EA R245CA R245FA R290 R32 R401A R401B. R401C R402A R402B R403A R403B R404A R405A R406A R407A R407B. R407C R407D R407E R408A R409A R409B R41 R410A R410B R411A. R411B R412A R413A R414A R414B R415A R415B R416A R417A R418A. R419A R420A R421A R421B R422A R422B R422C R422D R423A R424A. R425A R426A R427A R428A R50 R500 R501 R502 R503 R504. R507A R508A R507B R509A R600 R600A R707 R7441C02 R1234. Wide Range of applications. Pressure test: gauge pressure. Pressure test unit: Kpa; Mpa; bar; inHg; PSI. Pressure test range: 0 Kpa – 6000 Kpa. Pressure test resolution: 1 Kpa. Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt. Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;). Vacuum test: relative vacuum. Vacuum test unit: Kpa; Mpa; bar; inHg; PSI. Vacuum test range: -101 Kpa – 0 Kpa. Vacuum test resolution: 1 Kpa. Temperature test unit: °C (Celsius), °F (Fahrenheit). Temperature test range: -40°C-150°C (-40°F-302°F). 0.1°C (-40°C-99.9°C), 1°C (100°C-150°C). 0.1°F (-40°F-99.9°F), 1°F (100°F-302°F). Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt. Power Supplies: 4 X 1.5V SIZE. AA / LR6 Battery not include. Ancel AC3000 refrgerantion Digital Manifold Gauge. Clamp on temperature probe socket. 5, R+/R-Refrigerant Type Selection Buttons. 10, High Pressure Button. 11, Refrigerant Obezervation Window. 12, Pressure release valve. 13, Refrigerant inlet/vacuum Pump inlet. 14, Low Pressure Valve. 15,1/4 inch high pressure inlet. 1 x AC3000 Manifold Digital Meter. 1 x Paper Box. 1 x User Manual. Clean the exterior with a damp cloth. Do not use harsh solvents. Keep screw connections clean and free of grease, clean with a moist cloth as required. Carefully blow out oil residues in valve block using compressed air. Replace the batteries when low battery power indication lights on in LCD. Low battery power supply. The instruments has low power sign. When it is displayed, it means the battery power is insufficient. At this time, the battery should be replaced as required in order to avoid affecting normal use. Damaged refrigerant hose orvalve stem. Please check the pipe connections and hoses before testing. If you find any damage, please replace them immediately to avoid improper use or accident. Failure of refrigerant filling. There is a valve core in the refrigerant inlet of the refrigeration system. When connecting the instrument, pay attention the two terminals of the hoses. Connect one terminal with a core to the refrigeration system, while another terminal without acore to the instrument. Every hose terminal comes with a nylonpad that is limited a certain life of using. Over use or other situation will make itdefective, which result in leakage. The instrument refrigerant inlet (the middle port of the instrument) has a port with valve core, which is used to vent the air in the hoes after connecting the refrigerant to the instrument. The port is equipped with a copper plug screw. It is required to tighten it every time before or after operation. Check the refrigeration system’s pipes and connectors. Credit cards? Debit card? Apple Pay? Google Pay ect. Carrier and Logistics: All Orders are. Free repair for the devices. OBDII Code Reader, Car Diagnostic Tool, Truck Diagnostic Tool, EVAP Smoke Machine, Car Power Probe, Battery Tester. The price is reasonable and we have top rated after-sales service. Our main brand is. And we also sell other brands product, such as. FOXWELL, LAUNCH, THINKCAR, AUTOPHIX. GMT8 (9:00-18:00). From Monday to Friday.
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test

Posted by admin at October 18, 2023

Category: manifold

Tags: , , , , , , , , ,

Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test

Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test
ANCEL AC3000 digital manifold is a professisional instrument for installation, testing and maintenance of refrigeration equipment suchas air conditioners and cold stores. It combines 2-way pressure test, dual temperature measurements (with optionaldual temperature probes), a 32-bit digitalprocessor and a large LCD in one easy-to-useinstrument with the following main functions. Pressure and Saturation Temperature. Pressure Leak Test with recording. Direct T1 T2 Temperature, Real-timeSuperheat and Subcooling Simultaneously Display with Optional Two Clamp-onTemperature Probes. 5.89 Refrigerant Profiles Stored in The Instrument. Automatic Multi-unit Pressure Conversion. Automatic Temperature? /? Conversion. It is the right one you have to do the job right. Turn off the blue valve and red valve. Turn on the instrument. Then verify that LCD displays the status of the pressure test. If not, press the function button to switch it. When the instrument is turned on, theremay be 10 digits in the high and low pressure display area. Press R+/ R- buttons, Unit button and? /? Button to select tested refrigerant and reading display respectively. If the clamp-on temperature probes havebeen connected to the instrument, the real-time temperature will be displayed. If not, no display of it. Connect the instrument to the refrigeration system according to thechart below. Turn on the refrigerant valve and gently press the pressure release valve to vent the air in the connecting hose. When the refrigeration system stops, turnon the high pressure valve (red valve) and fill with a certain amount of refrigerant and then shut the valve quickly. Run the refrigeration system, turn on the low pressure valve (blue valve), and fill with the refrigerant into the refrigeration system. After the filling is completed, shut the low pressure valve (blue valve) and refrigerant valve. Let the refrigeration system running. Shut down the refrigeration system, make sure all valves are turned off, then disconnect the instrument between refrigeration system and source. Do not remove the high pressure valve connection until the pressure drops to the safe point. Then turn off the instrument. The filling operation of different equipment or refrigerants may vary. Please read carefully the relevant specific operation requirements for filling operation, so as to avoid damage to user or equipment caused by improper operation! The instrument can display the corresponding Evaporation Temperature(EV) and Condensation Temperature (CO) during the refrigerant pressure test. If the clamp-on temperature probes are connected to the instrument, LCD will display the real-time temperature in the spot T1 Sensor and T2 Sensor. Please make sure clamp-on temperature probes are connected as step 6 and contacted fully to the refrigeration pipes. The instrument can calculate the SH-Superheat and SC – Subcooling as long as the tested refrigerant ispreset and clamp-on temperature probes are connected well. Power on the instrument. Then make surethe LCD displays vacuum test status. If not, press the Function button to switch it. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. Press the unit button to adjust the reading unit. Connect the instrument to the refrigeration system. Connected clamp-on temperature probes will not affect the operation. Turn on the blue valve and red valve, andstart the vacuum pump. After the vacuum operation is completed, turn off the blue valve and red valve, then shut the vacuum pump. At this time, pressure leak test mode can be used to check leakage in the system (Please refer to Pressure Leak Test). The instrument is powered on with the blue and red valves turned off. Press the Function button to pressure leak test mode. The current pressure value is displayed at lower rightcorner of LCD. Press the Run/Stop button to start the leak test. At this time, the lower left corner records the initial pressure value; the lower right corner displays the instantaneous pressure value; the “P” display area shows the difference between the initial pressure value and the instantaneous pressure value. The time display shows how long the leak test will take, in hour : minute (HH:MM)format. All pressure units on the screen are the same. You can switch between the different pressure units by pressing the Unit button. 89 Kids of Refrigeant Database. Built-in 89 kinds of refrigerant NIST: According to AmericanNIST standard. R11 R113 R114 R115 R116 R12 R123 R124 R125 R1270. R13 R134A R14 R141B R142B R143A R152A R170 R21 R218. R22 R227EA R23 R236EA R245CA R245FA R290 R32 R401A R401B. R401C R402A R402B R403A R403B R404A R405A R406A R407A R407B. R407C R407D R407E R408A R409A R409B R41 R410A R410B R411A. R411B R412A R413A R414A R414B R415A R415B R416A R417A R418A. R419A R420A R421A R421B R422A R422B R422C R422D R423A R424A. R425A R426A R427A R428A R50 R500 R501 R502 R503 R504. R507A R508A R507B R509A R600 R600A R707 R7441C02 R1234. Wide Range of applications. Pressure test: gauge pressure. Pressure test unit: Kpa; Mpa; bar; inHg; PSI. Pressure test range: 0 Kpa – 6000 Kpa. Pressure test resolution: 1 Kpa. Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt. Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;). Vacuum test: relative vacuum. Vacuum test unit: Kpa; Mpa; bar; inHg; PSI. Vacuum test range: -101 Kpa – 0 Kpa. Vacuum test resolution: 1 Kpa. Temperature test unit: °C (Celsius), °F (Fahrenheit). Temperature test range: -40°C-150°C (-40°F-302°F). 0.1°C (-40°C-99.9°C), 1°C (100°C-150°C). 0.1°F (-40°F-99.9°F), 1°F (100°F-302°F). Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt. Power Supplies: 4 X 1.5V SIZE. AA / LR6 Battery not include. Ancel AC3000 refrgerantion Digital Manifold Gauge. Clamp on temperature probe socket. 5, R+/R-Refrigerant Type Selection Buttons. 10, High Pressure Button. 11, Refrigerant Obezervation Window. 12, Pressure release valve. 13, Refrigerant inlet/vacuum Pump inlet. 14, Low Pressure Valve. 15,1/4 inch high pressure inlet. 1 x AC3000 Manifold Digital Meter. 1 x Paper Box. 1 x User Manual. Clean the exterior with a damp cloth. Do not use harsh solvents. Keep screw connections clean and free of grease, clean with a moist cloth as required. Carefully blow out oil residues in valve block using compressed air. Replace the batteries when low battery power indication lights on in LCD. Low battery power supply. The instruments has low power sign. When it is displayed, it means the battery power is insufficient. At this time, the battery should be replaced as required in order to avoid affecting normal use. Damaged refrigerant hose orvalve stem. Please check the pipe connections and hoses before testing. If you find any damage, please replace them immediately to avoid improper use or accident. Failure of refrigerant filling. There is a valve core in the refrigerant inlet of the refrigeration system. When connecting the instrument, pay attention the two terminals of the hoses. Connect one terminal with a core to the refrigeration system, while another terminal without acore to the instrument. Every hose terminal comes with a nylonpad that is limited a certain life of using. Over use or other situation will make itdefective, which result in leakage. The instrument refrigerant inlet (the middle port of the instrument) has a port with valve core, which is used to vent the air in the hoes after connecting the refrigerant to the instrument. The port is equipped with a copper plug screw. It is required to tighten it every time before or after operation. Check the refrigeration system’s pipes and connectors. Credit cards? Debit card? Apple Pay? Google Pay ect. Carrier and Logistics: All Orders are. Free repair for the devices. OBDII Code Reader, Car Diagnostic Tool, Truck Diagnostic Tool, EVAP Smoke Machine, Car Power Probe, Battery Tester. The price is reasonable and we have top rated after-sales service. Our main brand is. And we also sell other brands product, such as. FOXWELL, LAUNCH, THINKCAR, AUTOPHIX. GMT8 (9:00-18:00). From Monday to Friday.
Manifold Digital Meter Temperature Gauge Air-Condition Vacuum Pressure Leak Test

Posted by admin at April 29, 2023

Category: manifold

Tags: , , , ,

ID Pro Manifold Gauge R22 R12 Refrigeration Air Conditioning HVAC AC
ID Pro Manifold Gauge R22 R12 Refrigeration Air Conditioning HVAC AC
ID Pro Manifold Gauge R22 R12 Refrigeration Air Conditioning HVAC AC
ID Pro Manifold Gauge R22 R12 Refrigeration Air Conditioning HVAC AC
ID Pro Manifold Gauge R22 R12 Refrigeration Air Conditioning HVAC AC
ID Pro Manifold Gauge R22 R12 Refrigeration Air Conditioning HVAC AC
ID Pro Manifold Gauge R22 R12 Refrigeration Air Conditioning HVAC AC
ID Pro Manifold Gauge R22 R12 Refrigeration Air Conditioning HVAC AC

ID Pro Manifold Gauge R22 R12 Refrigeration Air Conditioning HVAC AC
Vinatge Nos InterDynamics ProManifold Gauge R22 R12 Refrigeration Air Conditioning HVAC AC. Track Page Views With. This item is in the category “eBay Motors\Automotive Tools & Supplies\Diagnostic Service Tools\Other Diagnostic Service Tools”. The seller is “roadtripaholics” and is located in this country: US. This item can be shipped to United States, New Zealand, Fiji, Papua New Guinea, Wallis and Futuna, Gambia, Malaysia, Taiwan, Poland, Oman, Suriname, United Arab Emirates, Kenya, Argentina, Guinea-Bissau, Armenia, Uzbekistan, Bhutan, Senegal, Togo, Ireland, Qatar, Burundi, Netherlands, Iraq, Slovakia, Slovenia, Equatorial Guinea, Thailand, Aruba, Sweden, Iceland, Macedonia, Belgium, Israel, Kuwait, Liechtenstein, Benin, Algeria, Antigua and Barbuda, Italy, Swaziland, Tanzania, Pakistan, Burkina Faso, Panama, Singapore, Kyrgyzstan, Switzerland, Djibouti, Chile, China, Mali, Botswana, Republic of Croatia, Cambodia, Indonesia, Portugal, Malta, Tajikistan, Vietnam, Cayman Islands, Paraguay, Saint Helena, Cyprus, Seychelles, Rwanda, Bangladesh, Australia, Austria, Sri Lanka, Gabon Republic, Zimbabwe, Bulgaria, Czech Republic, Norway, Côte d’Ivoire (Ivory Coast), Kiribati, Turkmenistan, Grenada, Greece, Haiti, Greenland, Yemen, Afghanistan, Montenegro, Mongolia, Nepal, Bahamas, Bahrain, United Kingdom, Bosnia and Herzegovina, Hungary, Angola, Western Samoa, France, Mozambique, Namibia, Peru, Denmark, Guatemala, Solomon Islands, Vatican City State, Sierra Leone, Nauru, Anguilla, El Salvador, Dominican Republic, Cameroon, Guyana, Azerbaijan Republic, Macau, Georgia, Tonga, San Marino, Eritrea, Saint Kitts-Nevis, Morocco, Saint Vincent and the Grenadines, Mauritania, Belize, Philippines, Democratic Republic of the Congo, Republic of the Congo, Western Sahara, Colombia, Spain, Estonia, Bermuda, Montserrat, Zambia, South Korea, Vanuatu, Ecuador, Albania, Ethiopia, Monaco, Niger, Laos, Ghana, Cape Verde Islands, Moldova, Madagascar, Saint Pierre and Miquelon, Lebanon, Liberia, Bolivia, Maldives, Gibraltar, Hong Kong, Central African Republic, Lesotho, Nigeria, Mauritius, Saint Lucia, Jordan, Guinea, British Virgin Islands, Canada, Turks and Caicos Islands, Chad, Andorra, Romania, Costa Rica, India, Mexico, Serbia, Kazakhstan, Saudi Arabia, Japan, Lithuania, Trinidad and Tobago, Malawi, Nicaragua, Finland, Tunisia, Luxembourg, Uganda, Brazil, Turkey, Tuvalu, Germany, Egypt, Latvia, Jamaica, Niue, South Africa, Brunei Darussalam, Honduras.
  • Brand: Interdynamics
  • Tool Type: Kit Set
  • Type: Refrigeration Air Conditioning
  • Warranty: 90 Day
  • Custom Bundle: No
  • Manufacturer Part Number: MF-3
  • Country/Region of Manufacture: United States
  • Modified Item: No
  • UPC: 048168024353

ID Pro Manifold Gauge R22 R12 Refrigeration Air Conditioning HVAC AC

Posted by admin at August 17, 2022

Category: manifold

Tags: , , , , ,

1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table
1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table
1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table
1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table
1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table
1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table
1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table
1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table
1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table
1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table
1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table
1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table

1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table
Description The refrigerant recharge hose is made of premium material, corrosion resistance. Comes with pressure gauge, quick coupler adapter and refrigeration recharging hoses. Adopted special spring pressure indicator, precise gauge dial. Features – Color: As shown. Material: Metal and rubber. Size: 33 x 28 x 7. Reliable and safe for access systems even at working pressure. A great tool set for refrigerant testing, charging and evacuation. Premium refrigerant charging hoses are built for long life and dependability. Comes with high pressure resistant hose, easy to use and install. Adopted special spring pressure indicator, precise gauge dial. There could be some slight differences in the color and size between the photo and the actual item. Sincerely hope that you can understand! 1 x Air Conditioning Refrigerant Table Kit. We will not be responsible for item loss due to wrong or unknown address. We will offer solutions to such cases. We will get back to you as soon as we are available. We are always stand-by to help for any questions or concerns. This item is in the category “Vehicle Parts & Accessories\Garage Equipment & Tools\Air Conditioning Tools”. The seller is “kinminumall” and is located in this country: CN. This item can be shipped to all countries in Europe, Japan, Canada, Australia.
  • Brand: Unbranded
  • Manufacturer Part Number: as the picture
  • Material: Metal
  • MPN: Q0403171O5Z7L6U

1 Set Manifold Vacuum Gauge Set Air Conditioning Refrigerant Table

Posted by admin at December 15, 2021

Category: manifold

Tags: , , , , ,

4 Way Manifold Gauge Set to Suit R410a Refrigeration and Air Conditioning

4 Way Manifold Gauge Set to Suit R410a Refrigeration and Air Conditioning
Brand new Yellow Jacket 4way manifold with gauge lines and 2 spare gauges. High-pressure manifold from 0 bar. High-pressure manifold up to 60 bar. Low-pressure gauge from -1 bar. Low-pressure gauge up to 30 bar. Will be charged at cost. The item “4 Way Manifold Gauge Set to Suit R410a Refrigeration and Air Conditioning” is in sale since Saturday, December 5, 2020. This item is in the category “Business, Office & Industrial\HVAC & Refrigeration\HVAC & Refrigeration Tools\HVAC & Refrigeration\ Gauges & Probes”. The seller is “grf123red” and is located in Edinburgh, Edinburgh (City of). This item can be shipped to United Kingdom.
  • Gauge Purpose: Charging
  • Refrigerant: R-401a
  • Brand: YELLOW JACKET

4 Way Manifold Gauge Set to Suit R410a Refrigeration and Air Conditioning

Posted by admin at September 9, 2019

Category: manifold

Tags: , , , , ,

Ac Manifold Gauge Tool Set A/c Air Conditioning Diagnostic Kit Refrigeration New

Ac Manifold Gauge Tool Set A/c Air Conditioning Diagnostic Kit Refrigeration New
AC MANIFOLD GAUGE SET. Professional AC Manifold Gauge Set. For use with R-134A refrigerant Low pressure: 0220psi. Knurled fitting and twist valves. Blue(Low) Gauge: 0-220psi. Blue Hose: 1/4 in. FFL x 50 in. Read (high) Gauge: 0-500psi. Red Hose: 1/4 In. Yellow Hose: 1/2 in. ACME x 50 in. Gauge Accuracy: +/- 2%. If this is not possible please advise and we will endeavour to provide a solution. Any orders placed before 2pm will be dispatched same day. Please note if 1st class is selected, this is not a guaranteed next day service. For further details please see our Terms and Conditions below. Terms & Conditions – once you have received your goods please inspect them for any damages etc. Any message which has not been sent through e-bay will not receive a response. The item “AC MANIFOLD GAUGE TOOL SET A/C AIR CONDITIONING DIAGNOSTIC KIT REFRIGERATION NEW” is in sale since Thursday, June 2, 2016. This item is in the category “Vehicle Parts & Accessories\Garage Equipment & Tools\Air Conditioning Tools”. The seller is “click-buy-send” and is located in Congleton. This item can be shipped to United Kingdom.
  • Manufacturer Part Number: CT3622
  • Brand: NEILSEN

Ac Manifold Gauge Tool Set A/c Air Conditioning Diagnostic Kit Refrigeration New

Posted by admin at June 29, 2019

Category: manifold

Tags: , , , , , , ,

Manifold Gauge R134a R502a R22 R12 Refrigeration Air Conditioning HVAC AC Tools
Manifold Gauge R134a R502a R22 R12 Refrigeration Air Conditioning HVAC AC Tools
Manifold Gauge R134a R502a R22 R12 Refrigeration Air Conditioning HVAC AC Tools

Manifold Gauge R134a R502a R22 R12 Refrigeration Air Conditioning HVAC AC Tools
R134a R502a R22 R12 Refrigeration Air Conditioning AC Diagnostic Manifold Gauge. Complete diagnostic and service gauge set for use on air condition systems. Quick-connect fittings with high pressure safety valve. Color-coded gauges, valves and hoses. Operating Pressure: 500 PSI. Burst Pressure: 2500 PSI. ACME Adapter: 1/4″ Male to 1/2″ Female. Compatibility: R134A, R22, R12, R502. 1x R134A R22 R12 R502 Manifold Gauge. 1 x ACME Adapter. 2 x R134A Adapter Connector. Color Coded Hoses Set. We do not allow pickups. Once the order is paid we can’t change the address. Unfortunately, delays due to weekends, holidays, adverse weather conditions and carrier mistakes are out of our control. If you feel our S&H prices are too high, we can provide you weight the item’s weight so that you can confirm the prices for yourself. Undeliverable and Refused Item Policy. The item “Manifold Gauge R134a R502a R22 R12 Refrigeration Air Conditioning HVAC AC Tools” is in sale since Monday, June 13, 2016. This item is in the category “eBay Motors\Automotive Tools & Supplies\Diagnostic Service Tools\Other Diagnostic Service Tools”. The seller is “taztool” and is located in Long Beach, California. This item can be shipped to United States, Canada, United Kingdom, Denmark, Romania, Slovakia, Bulgaria, Czech republic, Finland, Hungary, Latvia, Lithuania, Malta, Estonia, Australia, Greece, Portugal, Cyprus, Slovenia, Japan, Sweden, South Korea, Indonesia, Taiwan, South africa, Thailand, Belgium, France, Hong Kong, Ireland, Netherlands, Poland, Spain, Italy, Germany, Austria, Bahamas, Israel, Mexico, New Zealand, Philippines, Singapore, Switzerland, Norway, Saudi arabia, Ukraine, United arab emirates, Qatar, Kuwait, Bahrain, Croatia, Malaysia, Chile, Colombia, Costa rica, Dominican republic, Panama, Trinidad and tobago, Guatemala, El salvador, Honduras, Jamaica, Antigua and barbuda, Aruba, Belize, Dominica, Grenada, Saint kitts and nevis, Saint lucia, Turks and caicos islands, Barbados, Bangladesh, Bermuda, Brunei darussalam, Bolivia, Ecuador, Egypt, French guiana, Guadeloupe, Iceland, Jordan, Cambodia, Cayman islands, Sri lanka, Luxembourg, Martinique, Maldives, Nicaragua, Oman, Peru, Pakistan, Paraguay, Reunion, Viet nam, Uruguay, Russian federation.
  • Country/Region of Manufacture: China
  • Manufacturer Part Number: 01045
  • Brand: ST
  • Tool Type: Kit Set

Manifold Gauge R134a R502a R22 R12 Refrigeration Air Conditioning HVAC AC Tools