Posts Tagged ‘tool’
ANCEL AC3000 digital manifold is a professisional instrument for installation, testing and maintenance of refrigeration equipment suchas air conditioners and cold stores. It combines 2-way pressure test, dual temperature measurements (with optionaldual temperature probes), a 32-bit digitalprocessor and a large LCD in one easy-to-useinstrument with the following main functions. Pressure and Saturation Temperature. Pressure Leak Test with recording. Direct T1 T2 Temperature, Real-timeSuperheat and Subcooling Simultaneously Display with Optional Two Clamp-onTemperature Probes. 5.89 Refrigerant Profiles Stored in The Instrument. Automatic Multi-unit Pressure Conversion. Automatic Temperature? /? Conversion. It is the right one you have to do the job right. Turn off the blue valve and red valve. Turn on the instrument. Then verify that LCD displays the status of the pressure test. If not, press the function button to switch it. When the instrument is turned on, theremay be 10 digits in the high and low pressure display area. Press R+/ R- buttons, Unit button and? /? Button to select tested refrigerant and reading display respectively. If the clamp-on temperature probes havebeen connected to the instrument, the real-time temperature will be displayed. If not, no display of it. Connect the instrument to the refrigeration system according to thechart below. Turn on the refrigerant valve and gently press the pressure release valve to vent the air in the connecting hose. When the refrigeration system stops, turnon the high pressure valve (red valve) and fill with a certain amount of refrigerant and then shut the valve quickly. Run the refrigeration system, turn on the low pressure valve (blue valve), and fill with the refrigerant into the refrigeration system. After the filling is completed, shut the low pressure valve (blue valve) and refrigerant valve. Let the refrigeration system running. Shut down the refrigeration system, make sure all valves are turned off, then disconnect the instrument between refrigeration system and source. Do not remove the high pressure valve connection until the pressure drops to the safe point. Then turn off the instrument. The filling operation of different equipment or refrigerants may vary. Please read carefully the relevant specific operation requirements for filling operation, so as to avoid damage to user or equipment caused by improper operation! The instrument can display the corresponding Evaporation Temperature(EV) and Condensation Temperature (CO) during the refrigerant pressure test. If the clamp-on temperature probes are connected to the instrument, LCD will display the real-time temperature in the spot T1 Sensor and T2 Sensor. Please make sure clamp-on temperature probes are connected as step 6 and contacted fully to the refrigeration pipes. The instrument can calculate the SH-Superheat and SC – Subcooling as long as the tested refrigerant ispreset and clamp-on temperature probes are connected well. Power on the instrument. Then make surethe LCD displays vacuum test status. If not, press the Function button to switch it. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. Press the unit button to adjust the reading unit. Connect the instrument to the refrigeration system. Connected clamp-on temperature probes will not affect the operation. Turn on the blue valve and red valve, andstart the vacuum pump. After the vacuum operation is completed, turn off the blue valve and red valve, then shut the vacuum pump. At this time, pressure leak test mode can be used to check leakage in the system (Please refer to Pressure Leak Test). The instrument is powered on with the blue and red valves turned off. Press the Function button to pressure leak test mode. The current pressure value is displayed at lower rightcorner of LCD. Press the Run/Stop button to start the leak test. At this time, the lower left corner records the initial pressure value; the lower right corner displays the instantaneous pressure value; the “P” display area shows the difference between the initial pressure value and the instantaneous pressure value. The time display shows how long the leak test will take, in hour : minute (HH:MM)format. All pressure units on the screen are the same. You can switch between the different pressure units by pressing the Unit button. 89 Kids of Refrigeant Database. Built-in 89 kinds of refrigerant NIST: According to AmericanNIST standard. R11 R113 R114 R115 R116 R12 R123 R124 R125 R1270. R13 R134A R14 R141B R142B R143A R152A R170 R21 R218. R22 R227EA R23 R236EA R245CA R245FA R290 R32 R401A R401B. R401C R402A R402B R403A R403B R404A R405A R406A R407A R407B. R407C R407D R407E R408A R409A R409B R41 R410A R410B R411A. R411B R412A R413A R414A R414B R415A R415B R416A R417A R418A. R419A R420A R421A R421B R422A R422B R422C R422D R423A R424A. R425A R426A R427A R428A R50 R500 R501 R502 R503 R504. R507A R508A R507B R509A R600 R600A R707 R7441C02 R1234. Wide Range of applications. Pressure test: gauge pressure. Pressure test unit: Kpa; Mpa; bar; inHg; PSI. Pressure test range: 0 Kpa – 6000 Kpa. Pressure test resolution: 1 Kpa. Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt. Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;). Vacuum test: relative vacuum. Vacuum test unit: Kpa; Mpa; bar; inHg; PSI. Vacuum test range: -101 Kpa – 0 Kpa. Vacuum test resolution: 1 Kpa. Temperature test unit: °C (Celsius), °F (Fahrenheit). Temperature test range: -40°C-150°C (-40°F-302°F). 0.1°C (-40°C-99.9°C), 1°C (100°C-150°C). 0.1°F (-40°F-99.9°F), 1°F (100°F-302°F). Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt. Power Supplies: 4 X 1.5V SIZE. AA / LR6 Battery not include. Ancel AC3000 refrgerantion Digital Manifold Gauge. Clamp on temperature probe socket. 5, R+/R-Refrigerant Type Selection Buttons. 10, High Pressure Button. 11, Refrigerant Obezervation Window. 12, Pressure release valve. 13, Refrigerant inlet/vacuum Pump inlet. 14, Low Pressure Valve. 15,1/4 inch high pressure inlet. 1 x AC3000 Manifold Digital Meter. 1 x Paper Box. 1 x User Manual. Clean the exterior with a damp cloth. Do not use harsh solvents. Keep screw connections clean and free of grease, clean with a moist cloth as required. Carefully blow out oil residues in valve block using compressed air. Replace the batteries when low battery power indication lights on in LCD. Low battery power supply. The instruments has low power sign. When it is displayed, it means the battery power is insufficient. At this time, the battery should be replaced as required in order to avoid affecting normal use. Damaged refrigerant hose orvalve stem. Please check the pipe connections and hoses before testing. If you find any damage, please replace them immediately to avoid improper use or accident. Failure of refrigerant filling. There is a valve core in the refrigerant inlet of the refrigeration system. When connecting the instrument, pay attention the two terminals of the hoses. Connect one terminal with a core to the refrigeration system, while another terminal without acore to the instrument. Every hose terminal comes with a nylonpad that is limited a certain life of using. Over use or other situation will make itdefective, which result in leakage. The instrument refrigerant inlet (the middle port of the instrument) has a port with valve core, which is used to vent the air in the hoes after connecting the refrigerant to the instrument. The port is equipped with a copper plug screw. It is required to tighten it every time before or after operation. Check the refrigeration system’s pipes and connectors. Greenwich Mean Time will be delivered on the same day! 12 months free repair for the devices. 3 months for the accessories. The price is reasonable and we have top rated after-sales service. Our agent brands are: ANCEL, FOXWELL, LAUNCH, THINKCAR, AUTOPHIX, etc. We promise to help you solve it asap, and make you feel satisfactory absolutely. After you received our package you are satisfied with it. We will do the same as soon as we can too.
COILOVER adjust tool COIL SHOCK SPRING SLEEVE ADJUSTMENT SPANNER 2 PCS Sales. BFO 3pc Car Auto Repair Rear Axle Bearing Puller Extractor Tool Set CT3368. Engine Camshaft Alignment Locking Timing Tool For Mercedes A-B-C Class M133 M270. TIMING LOCKING TOOLS SET N12 N14 R55 R56 1.4 1.6 FOR BMW PEUGEOT CITROEN. Air Conditioning Refrigeration Diagnostic Tool Dual Manifold Gauges Valve R21. We know our products. Always the correct part. Purpose: This manifold instrument kit eliminates your HVAC problems in the bud. The enhanced hybrid pressure gauge combines the best functions of both dry and liquid filled pressure gauges, providing durable cold and seismic resistance services. Their calibration screws and humidity indicators provide accurate readings and rapid monitoring of coolant conditions. Scope of application: This car’s air conditioning instrument cluster is suitable for R410a and R134a coolants. With 2 adjustable connectors and a piercing faucet, you can charge the system without worry, and the inclining and straight adapters provide maximum reachability. High quality materials, this automotive communication instrument cluster is made of high-quality brass and aluminum, with long-lasting strength and corrosion resistance. Easy to carry: It is equipped with a heavy foam lined suitcase for easy storage and transportation between jobs. Hose Length: 5 ft. Automotive A/C Manifold Gauge Set Charging or Diagnostic. 1/2″ ACME ADAPTER (1/2″ Female to 1/4 Male). Max working pressure: 800PSI. Blue Gauge (Low): 2-1/2 diameter, 0-550 PSI. Red Gauge (High): 2-1/2 diameter, 0-750 PSI. Red and Blue 60″ long charging hose R12, R22, R134A, R410A (1/4″ x 60). Yellow 60″ long charging hose R12, R22, R134A R410A SAE (5/8″ x 60). 4 x Hoses 2 x Adapters 1 x Manifold Gauge Set 1 x 1/2″ACEM 1 x 1/4″ACEM 1 x Valve Spanner 1 x three-color Tube Backup set 1x Carry Case. Will this fit my car? When will my order be dispatched? Can I amend my order? What do I do if I have not received my order? What do I do if my product is faulty? It will speed up the process if you could provide us some pictures or video to illustrate the issue details. Other items you might also like. Pair Blue Coilovers Adjustment Tool Steel Spanner Wrenchs for Coilovers. Timing Tool Kit For Opel Vauxhall GM 1.3 cdti 16v, 1.9 cdti, 2.0 dti, 2.2 dti. Red Valve Spring Compressor Tool For Honda Acura B-Series VTEC Head B16A B18C. Diesel Engine Timing Tool for BMW N47 N47S 2.0 D20A 318D 320D 520D. Fuel Pump Socket 69800 For Volvo S60 S80 V70 XC70/90 Lock Ring Removal Tool. Engine Timing Tool Kit For BMW M54B22 E46 320i/320Ci E39 520i E85 Z4 2.2i. 10x Wheel Bearing Race Seal Driver Insert Installer Tool Kit 9.5mm 44.5mm. Air Conditioning Manifold Refrigeration Tools Gauge Tester AC Diagnostic Kit UK. Every message will be replied within 12 hours on 7×24 hours. 7×24 hours, always here for you.
High Quality Manifold Gauge & Feron-Adding Gauge For R134A Refrigerant. With 3pieces 1.5m long hose and 2500psi max explosion pressure.
Collecting listings has surprises. It is one of the best choices for you. Are you looking for a professional, yet affordable refrigerant leak detector? Are you in search of a sturdy, trustworthy tool that can do multiple jobs at once? If yes, look no further! Our refrigerant leak detector must meet your needs Features Probe length: 20cm Maximum sensitivity: For halogen refrigerant, 6gr/ – Built-in high-precision voltage regulator IC and the ultra-low power consumption design make the work more stable and the battery more durable. Working temperature: 0-52 Celsius degree – Fine workmanship, durable and sturdy, not easy to wear or tear, you deserve to have one. The sensitivity can be adjusted at any time, and the instrument can be automatically adjusted to the best detection state. Warm-up time: about 6 seconds Reset time: 2-10 seconds Response Time: Instantaneous – It has the function of power-on reset and automatic follow-up, which can ignore the concentration level of halogen gas in the environment. Mode: unlimited Power supply: 4 x AAA batteries (not included) – Indicator lights on the front of the panel are used for leak warning and battery voltage indication. Battery Life: About 50 hours under normal use -Color: Yellow -Material: ABS – Size: 15.00X4.50X3.50cm/5.89X1.77X1.38in. 1 x refrigerant leak detector.
One of perfect products for your own car. Easy to read the readings and precise display. Built-in ball valve, easy to open and close. Rubber sheath to protect the pressure gauge from damage. Glass observation hole, at the user can observe the of the refrigerant. Condition:100% Brand New. Color: As shown in the picture. Suitable for refrigerant: R134A, R12, R22, R410A, R404A, etc. Accuracy: 1.6 level, high shock resistance. Pointer range: high pressure: -30800PSI (-155bar). Low pressure: -30500PSI (-135bar). High quality fluoride tube. 31.5 m Inflatable Hose. 2Adjustable Joint A / C Quick Joint (red = high pressure, blue = low pressure). Because there was a manual measuring, the size may has 1-2cm/inch difference. We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. Post a message again because sometimes our message system may block some emails. If you are satisfied with our service, pls. Our aim is to provide Level Customer Service, your recognition will encourage us greatly and serve you better. We strive to keep all our customers satisfy. We will do our up most to exceed your expectations in customer service, communication and dispatching of your orders.
Collecting listings has surprises. Description This is a very practical refrigerant leak detector. The exquisite craftsmanship can serve you well without breaking easily. The refrigerant leak detector is convenient and practical, with excellent texture, and can serve you for a long time without being easily damaged Features Reset time: 2-10 seconds Probe length: 20cm Working temperature: 0-52 Celsius degree Maximum sensitivity: For halogen refrigerant, 6gr/ Warm-up time: about – Power-on reset: After the instrument is turned on, it can automatically adjust the circuit within 6S to ignore the existing probe. Power supply: 4 x AAA batteries (not included) – Sensitivity adjustment: This product has the function of stepless adjustment of sensitivity, which can be adjusted at any time during detection. When the refrigerant concentration level is reached, it enters the detection state. If the user turns on the look for sources of higher concentrations of leaks. The instrument can also be turned on in clean air to adjust to maximum sensitivity, at which point leaks above the zero concentration level can be detected. Auto-following circuit: When the instrument is in the detection state, the automatic circuit will follow the halogen in the environment. Changes in the concentration of the element gas to prevent false alarms. When the leaked gas is found, the warning sound will become more rapid, and the more leakage, the more rapid the warning sound. At the same time, the indicator light flashes quickly. Response Time: Instantaneous Mode: unlimited Battery Life: About under normal use -Color: Yellow -Material: ABS – Size: 15.00X4.50X3.50cm/5.89X1.77X1.38in. 1 x refrigerant leak detector.
HVAC A/C Refrigeration Kit AC Manifold Gauge Set Auto Service Kit Car Air Conditioning Repair Fluorine.
This is a very practical refrigerant leak detector. Maximum sensitivity: For halogen refrigerant, 6gr/. When the refrigerant concentration level is reached, it enters the detection state. If the user turns on the look for sources of higher concentrations of leaks.
2 Adjustable Joint A / C Quick Joint (red = high pressure, blue = low pressure). Built-in ball valve, easy to open and close. 1 R134a Bottle Opener. Accuracy: 1.6 level, high shock resistance.
When the refrigerant concentration level is reached, it enters the detection state. If the user turns on the look for sources of higher concentrations of leaks. 1 x refrigerant leak detector. Size: 15.00X4.50X3.50cm/5.89X1.77X1.38in.